Factual, Authentic and Truthful Reports!
Because the law requires that we may not publish in print the names of
the well-recognized Laboratories who have issued the following Test
results unless we receive their written Consent and Release, which
will not be granted (due to the fear that many potential consumers of
System"48-PLUS" will swamp their phone lines for verification)
-we legally cannot reveal their identities... but we can do the next
best thing by issuing the following statement:
CERTIFICATION!
I, as Engineer and Executive Vice President of The Cromwell
Organization, Inc., do hereby Swear and Certify that all Laboratory
Tests as contained within-have been conducted by the most reputable
Independent Laboratories-and their original signed reports and
conclusions described, can be viewed and inspected by any person
visiting our premises during normal business hours.
Signed; Nazar Aldulaimi
1. "WEAR" TEST!
Highly esteemed and respected Independent Laboratory issues this report
after testing System "48-PLUS" for wear on metal!
PROJECT NO. 01352
REPORT TO: The Cromwell Organization, LTD
We were authorized to evaluate a submitted sample of System "
48-PLUS". The material was evaluated by use of The Falex Tester
for its ability to prevent wear on metal.
The following test method was used to determine the wear prevention
of metal using System "48-Plus".
Method:
The test was performed using a Falex Tester manufactured by Faville
Le Valley Corporation.
Test pieces were standard pieces supplied by Faville Le Valley Corporation.
Each test fluid was added to the machine and the ASTM D-3233 test
procedure was used up to a load of 850 pounds.
The test load of 850 pounds was maintained for 11/2 hours.
At the end of the test period, the test metal rod was measured for
wear and compared to its initial value.
The amount of wear was then recorded.
Test:
SYSTEM "48-PLUS" WAS EVALUATED AT A DILUTION OF 2 0Z./QUART
WITH QUAKER STATE l0W-40 MOTOR OIL.
THE QUAKER STATE l0W-40 MOTOR OIL WAS ALSO EVALUATED ALONE.
Results:
Wear on test specimen Product: (1.5 hours @ 850 Ibs. load)
Quaker State l0-40 Motor Oil.......................................... 0.008"
System "48-PLUS" - Quaker State 10W-40 Motor Oil- 2 oz./quart......... 0.002"
2. GAS MILEAGE TESTS!
World-Famous Independent Laboratory issues this report after testingSystem "
48-PLUS"! for Gas Mileage!
Introduction
The testing described in this report was conducted in accordance with the United
States Environmental Protection Agency procedures.
Additive Mixture:
The Engine Formula was labeled System "48-PLUS". Unleaded fuel was used
for all of the tests.
Method of Test:
"Hot 505" baseline and System "48-PLUS" tests were performed
for research and development purposes.
Scope of Project:
To establish the effect of System"48-PLUS" on fuel economy of two passenger
cars after 1,000 miles of driving these vehicles with this formula added to the engines.
Test Procedure:
All tests were run on the dynamometer, and were based on the Federal Test procedure as
described in the Federal Register Part 86, Subpart B. The tests were limited to only
the hot transient portion of the driving cycle and the vehicles were not in the "
cold start" mode prior to testing. This type of testing is commonly referred to
as "Hot 505". In this procedure, fuel economy values using the carbon balance
of calculation, are obtained.
|